When I hear that a 91C-8 needs several button presses to start, I know that each delay can interrupt hose production and make the fault hard to trace.
I start by checking the 24 V DC control supply, solenoid coil, wiring, relay, and button signals while the fault is present. If heating changes the control board’s behavior, I inspect or replace the board. After replacement, I verify the connections and adjust the die-change stop setting.
I worked through this fault with a customer by asking for video, checking one part at a time, and reviewing the result after every change. The first symptom was a slow start after the machine had been switched off for a while. Later, after the control board was replaced, the machine moved but did not stop at the end of the die-change cycle. I’ll explain how I followed both symptoms and what I checked before the machine returned to normal operation.
Why Did the 91C-8 Need Several Button Presses to Start?
I take a slow or delayed start seriously because it can point to an intermittent control problem, even when the machine runs normally once it begins moving.
I first check whether the fault appears after the machine has been off for a long time. I then ask a qualified technician to measure the 24 V DC supply and check the solenoid coil while the fault is happening.
I compare the machine’s behavior before and after it starts
The customer told us that the machine sometimes needed several button presses before it moved. Once it started, it worked normally. The problem appeared again only after the machine was switched off and left for a long time. That detail helped me focus on an intermittent electrical fault instead of assuming that the hydraulic system was always too slow.
I asked the customer to check whether the control supply delivered 24 V DC. A reading taken only while the machine was working could miss a fault that appeared during startup. I wanted the technician to observe the voltage when the machine failed to respond, and to check the solenoid coil and its connections at the same time.
| What I checked | What the check could tell me |
|---|---|
| 24 V DC supply during the fault | I could see whether the control voltage dropped or became unstable. |
| Solenoid coil and wiring | I could check whether the coil received power and responded to the control signal. |
| Startup after a long rest | I could compare the fault condition with normal operation. |
The customer replaced the solenoid coil, but the delayed startup still happened. The voltage reading also changed with the button signal. That result showed me that a coil replacement alone had not fixed the problem. I moved on to the control circuit and its connections.
How Did I Check the Relay, Wiring, and Buttons?
I check the simple control parts before I conclude that a circuit board has failed. A loose relay, weak connection, or faulty button can interrupt the signal and create an intermittent problem.
I ask a qualified technician to inspect the wiring and relay, then test the buttons for continuity with the machine safely isolated from power.
I use the indicator lights and meter results as clues
I asked the customer to check the wire terminals and the small relay. The customer checked the wire ends and replaced the relay, but the fault remained. This result helped me rule out a simple loose relay as the only cause.
During the fault, the customer reported that the indicator on the control board lit when a button was pressed, while the light at the bottom of the button did not. That difference made me suspect the button or its signal path. I asked an electrician to test each button with a multimeter on the continuity setting. The electrician reported that the buttons themselves worked normally.
I treat each result as evidence, but I do not treat one normal reading as proof that the whole circuit is sound. A button can pass a continuity check while a connector, board input, or solder joint still has an intermittent contact. I also avoid telling customers to bridge control wires or probe a live board themselves. A qualified technician should make electrical measurements and should isolate power before checking continuity.
At this stage, the supply, coil, relay, wiring ends, and buttons had all been checked or changed without solving the problem. I needed to look at the control board itself.
What Did It Mean When Heating the Board Restored Operation?
I treat a temporary improvement after heating a control board as a warning sign. It can point to a temperature-sensitive connection or board fault, but it does not prove which component has failed.
I do not consider heating a repair. I use the result as a clue, then ask a qualified technician to inspect the board or replace it.
I use the heat response as a clue, not a final diagnosis
The customer said that the machine began working when the control board was warmed slightly with a hot-air tool. The machine stopped responding again when the board was no longer warm. I took that result seriously because it suggested that the fault could be sensitive to temperature or contact.
I did not treat the hot-air test as proof of a cracked solder joint. A board can respond to heat for more than one reason, and the test did not identify the exact component. The customer said that the machine had been in use for about five years. We considered that a weak solder joint or connection could have developed over time, but I could not confirm that from the video alone.
I advised the customer to have the board inspected and to repair or replace it if needed. I would not tell an operator to keep heating the board, since that could damage components and leave an electrical hazard. The customer installed a replacement control board. That changed the machine’s behavior, but it did not finish the troubleshooting. The machine could move forward and backward, while the die-change mode still did not stop automatically when the dies closed. I treated this as a new adjustment problem to check.
Why Did the Replacement Board Still Need Adjustment?
I check the board connections and machine settings after a control board replacement. The machine may move but still need its die-change stop point set correctly.
I confirm the connector positions against the board instructions, enter the correct setting mode, and adjust the stop value in small steps based on the machine’s actual movement.
I separate movement from the stop-point problem
After the new board was installed, the customer reported that the machine moved forward and backward. The remaining fault appeared in die-change mode: the dies closed to their limit, but the machine did not stop automatically. This was different from the original slow-start symptom, so I checked the mode and stop setting rather than repeating the first tests.
I asked the customer to compare the replacement board’s connector positions with the board diagram. The customer also shared a display reading of 61.00. I did not assume that this number alone identified the fault, because the correct display values depend on the board setup and machine configuration. I asked the customer to enter the die-change mode, then hold the OK and right-arrow buttons until the board beeped. The customer could then press OK to move through the setting items.
When we reached item 6, I asked the customer to adjust the value with the plus and minus buttons and watch where the dies stopped. In this case, the initial value was 0.6, and we suggested trying 2.6 or 3.6 as a starting point. I told the customer to adjust in small steps based on the actual stopping position. The customer later tried values as high as 99.6 without seeing a change. That told me not to keep increasing the number blindly. I needed to confirm the mode, connector positions, sensor response, and whether the setting was taking effect.
| Adjustment check | How I used it |
|---|---|
| Correct mode | I confirmed that the machine was in die-change mode before changing the stop setting. |
| Correct setting item | I used the control panel to reach item 6. |
| Actual stopping point | I used the die movement to decide whether to raise or lower the value. |
| No response to changes | I stopped guessing and checked the setup and sensor signal again. |
How Did I Confirm That the Machine Was Working Normally?
I confirm a repair by testing the functions linked to the original fault. A machine that moves once does not prove that an intermittent startup or an automatic stop problem has been fixed.
I test forward and reverse movement, die closure in die-change mode, and the crimping stop point. I also retest after the machine has been off for a while.
I test the fault conditions again after each repair
I asked the customer to confirm whether normal crimping worked and whether the dies stopped at the set size. The customer later reported that the machine was working normally again. My service notes do not record the final setting value or the exact last adjustment, so I do not claim that one number will solve this fault on every 91C-8.
I use the same approach when I check a machine after repair. I test forward and reverse movement, then I run the die-change cycle and confirm that the machine stops at the correct point. I also check a sample crimp and confirm that the machine stops when it reaches the required setting. Because this customer first saw the fault after a long rest, I would also switch the machine off, leave it for a while, and test startup again.
I keep the test area clear and keep hands away from the dies during operation. I ask a qualified technician to handle any electrical checks. I also record the display values, connector positions, and test results before and after an adjustment. Those notes make remote troubleshooting clearer and help me avoid repeating changes that did not affect the fault.
Conclusion
I traced the 91C-8 fault through its 24 V control circuit, relay, buttons, board, connectors, and die-change setting until the customer confirmed normal operation.
About CYT-HYDRAULIC
I am Xiaoyan Lu, founder of CYT-HYDRAULIC. I started in the hydraulic products trade and built a company that supplies hose crimpers, hydraulic hoses, and fittings. I share practical experience to help customers make reliable, leak-free hose assemblies and keep construction machinery working smoothly.